BQBPF - COLORIZER SATIN GLOSS-WATERPROOF EN, 2100 P

  • MSDS: BQBPF
  • Manufacturer: CALIFORNIA PRODUCTS CORP
  • Product Name: COLORIZER SATIN GLOSS-WATERPROOF EN, 2100 P
  • National Stock Number: 8010-00N034344
Product Identification

Product ID:COLORIZER SATIN GLOSS-WATERPROOF EN, 2100 P
MSDS Date:05/03/1989
FSC:8010
NIIN:00N034344
MSDS Number: BQBPF

Responsible Party
CALIFORNIA PRODUCTS CORP
169 WAVERLY ST
CAMBRIDGE, MA 02139
US

Emergency Phone: 508-887-5926;800-424-9300(CHEMTREC)

Info Phone: 617-547-5300

Cage: 08750

Contractor
CALIFORNIA PRODUCTS CORP
CAMBRIDGE, MA 02139 US

Telephone: 617-547-5300 EXT 208

Cage: 08750

Ingredients

0.13 (BU AC=1)

CAS: 8030-30-6

RTECS: DE3030000

Fraction By Weight: 27%

OSHA PEL 500 PPM


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


CALCIUM CARBONATE

CAS: 1317-65-3

RTECS: EV9580000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


CLAY; (KAOLIN)

CAS: 1332-58-7

RTECS: GF1670500

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 2 MG/M3 TDUST; 9293


PIGMENTS


HEAVY SOLVENT VAPORS SHOULD BE REMOVED FROM THE LOWER

RTECS: 9999999ZZ


EXPLOSION PROOF EQUIP) SHOULD BE ELIMINATED IF

RTECS: 9999999ZZ


AREAS SHOULD BE VENTILATED IN ACCORDANCE WITH OSHA

RTECS: 9999999ZZ


FULL FACE SHIELD, APRON, OR OTHER

RTECS: 9999999ZZ


SHOULD NOT BE CONSUMED ANYWHERE THIS

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NOTE:INTENTIONAL MISUSE BY
DELIBERATELY CONC & INHAL FUMES MAY BE HARMFUL. ACUTE:ANESTHETIC.
IRRIT. MAY CAUSE HDCH & NAUS. IRRIT OF THE RESP TRACT/CNS
DEPRESSION CHARAC BY THE FOLLOWING PROGRESSIVE ST EPS: HDCH, DIZZ,
STAG GAIT, CONFUSION, UNCON/COMA. CHRONIC:MAY CAUSE RESP SENSIT,
LIVER/KIDNEY DMG. MAY(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: CAUSE SKIN SENSIT. PERMANENT CNS
CHANGES CAN OCCUR BECAUSE OF SOLVENT EXPOSURE.
Medical Cond Aggravated by Exposure:RESPIRATORY ALLERGIES. CHRONIC
DISEASES OF THE SKIN, NOSE, THROAT AND LUNGS, CNS, LIVER, KIDNEY,
BLOOD, EYES.

First Aid

First Aid:INHAL:MOVE PERSON TO FRESH AIR. RESTORE BRTHG. TREAT
SYMPTOMATICALLY. CONSULT A PHYSICIAN. EYES:FLUSH IMMED W/LRG AMTS
OF H*2O FOR AT LEAST 15 MIN. TAKE TO A PHYSICIAN FOR MED TREATMENT.
SKIN:WASH AFF ECTED AREAS W/SOAP & H*2O. REMOVE CONTAM CLTHG.
CONSULT A PHYSICIAN IF IRRIT PERSISTS. INGEST:CALL A PHYSICIAN
IMMED. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. TREAT
SYMPTOMATICALLY.

Fire Fighting

Flash Point Method:SCC
Flash Point:103F,39C
Lower Limits:1.1%
Upper Limits:5.9%
Extinguishing Media:FOAM, DRY CHEMICAL OR CARBON DIOXIDE.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SUPPLIED-AIR BRTHG EQUIP
& FULL PROT EQUIP FOR ENCLOSED AREAS. COOL EXPOSED CONTAINERS
W/H*2O SPRAY. MIN BRTHG VAPORS/FUMES.
Unusual Fire/Explosion Hazard:DO NOT MIX/STORE W/STRONG OXIDANTS SUCH
AS LIQ CHLORINE/CONC OXYGEN. "EMPTY" PROD CNTNRS RETAIN PROD
RESIDUE. DO NOT PRESSURIZE, CUT, HEAT, WELD, (SUPP DATA)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION (FLAME, HOT
SURFACES, AND ELECTRICAL, STATIC OR FRICTIONAL SPARKS). AVOID BRTHG
VAPORS. USE NIOSH/MSHA APPROVED SCBA. VENT AREA. CONTAIN AND REMOVE
WITH INERT ABSORBENT MATERIAL AND NON-SPARKING TOOLS. AVOID
CONTACT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE/USE NEAR HEAT/OPEN FLAME.
REFER TO OSHA 79CFR PART 1910.106 FOR SPECIFIC STORAGE REQUIREMENT.
DO NOT GET IN EYES.
Other Precautions:KEEP CLOSURE TIGHT & CNTNR UPRIGHT TO PVNT LEAKAGE.
DRUMS OF THIS MATL SHOULD BE GROUNDED & BONDED WHEN POURING. DO NOT
WELD/FLAME-CUT EMPTY DRUMS. AVOID SKIN CNTCT. CAN CAUSE ALLERGIC
RESP RXN. CAN C AUSE ALLERGIC SKIN RXN. PVNT (SUPP DATA)

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED CHEMICAL/MECHANICAL
FILTERS DESIGNED TO REMOVE A COMBINATION OF PARTICULATES AND
ORGANIC VAPOR IN OPEN AND RESTRICTED VENTILATION AREAS. USE
NIOSH/MSHA APPROVED AIRLINE TYPE RE SP OR HOOD IN CONFINED AREAS.
Ventilation:SUFFICIENT VENT, IN PATTERN & VOL, SHLD BE PROVIDED TO KEEP
THE AIR CONTAM CONC BELOW APPLIC EXPOS LIMITS. (ING 6)
Protective Gloves:NEOPRENE OR RUBBER.
Eye Protection:CHEM WORK GOGG/FULL LENGTH FSHLD .
Other Protective Equipment:USE DISPOSABLE OR IMPERVIOUS CLTHG IF WORK
CLTHG CONTAM IS LIKELY. USE PROT CREAM IF SKIN CNTCT IS LIKELY. USE
(ING 9)
Work Hygienic Practices:WASH HANDS BEFORE EATING, SMOKING/USING
WASHROOM. DO NOT SMOKE IN ANY CHEM HNDLG/STORAGE AREA. FOOD &
BEVERAGES (ING 10)
Supplemental Safety and Health
SPEC GRAV:1.37 (H*2O=1). EXPLO HAZ: OR EXPOSE SUCH CONTAINERS TO
FLAME; THEY MAY EXPLODE AND CAUSE INJURY OR DEATH. OTHER PREC:
PRLNGD/RPTD BRTHG OF VAPOR OR SPRAY MISTS. DO NOT HANDLE UNTIL TH E
MFR SAFETY PREC HAVE BEEN READ & UNDERSTOOD. DO NOT WELD/FLAME-CUT
AN EMPTY DRUM. AVOID BREATHING SANDING DUSTS.

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:>302F,>150C
Vapor Pres:2 @ 68F
Vapor Density:HVR/AIR
Spec Gravity:SUPP DATA
Evaporation Rate & Reference:ING 1
Solubility in Water:NIL
Appearance and Odor:VISCOUS LIQUID SLIGHT PETROLEUM ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
AMINES, ACIDS, HYDROXYL OR OTHER ACITIVE HYDROGEN COMPOUNDS.
Stability Condition to Avoid:HIGH TEMPERATURES.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:DISPOSAL SHOULD BE DONE IN ACCORDANCE WITH
FEDERAL (40 CFR PART 261), STATE AND LOCAL REGULATIONS. BEFORE
ATTEMPTING CLEAN-UP, REFER TO HAZARD CAUTION INFORMATION IN OTHER
SECTIONS OF THE MSDS. USE LI CENSED HAZARDOUS WASTE DISPOSAL
CONCERN.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.